Test Jacks
Two test jacks are located on the front panel: NET
MON (Network Monitor) In and NET MON Out.
NET MON In nonintrusively monitors the signal going
into the network.
NET MON Out nonintrusively monitors the signal
coming from the network.
Test Commands
The test commands enable you to run loopbacks and
test patterns on the DSU/CSU, and to test the front panel
LEDs. These tests can help you isolate areas of trouble if
you are having problems with your DSU/CSU.
To access all Test commands from the Test branch,
press F2 to select Test from the top-level menu screen.
F1
DSU ESF
Stat Test Cnfig
F2
F3
Remote Loopback Tests
The Remote Loopback tests enable you to troubleshoot
your circuit by sending the following to a far-end device:
For Networks
Line loopback up activation sequence for
10 seconds (LLBUP)
Line loopback down activation sequence for
10 seconds (LLBDN)
For Channels
V.54 activation sequence to initiate a V.54 Loop 2
(54UP)
V.54 deactivation sequence to terminate a V.54
Loop (54DN)
ANSI T1.403 (Annex B) activation sequence to
initiate a DCLB on the remote device (FT1UP)
ANSI T1.403 (Annex B) deactivation sequence to
terminate a DCLB on the remote device (FT1DN)
You cannot perform remote loopbacks if any of the
local loopbacks are active. If you attempt to do so, the
error message Invld Test Combo (Invalid Test
Combination) appears.
Sending a Line Loopback Up or Down
" Procedure
To send a Line Loopback Up or Down sequence on the
network to a far-end DSU/CSU:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Rlpbk.
F1
Test:
Rlpbk Lpbk Ptrns
F2
F3
3. From the Rem Loopback screen, press F1 to select
LLBUP (Line Loopback Up), or press F2 to select
LLBDN (Line Loopback Down).
F1
Rem Loopback:
LLBUP LLBDN 54UP
F2
F3
The Line Loopback sequence is sent up or
downstream to the far-end DSU/CSU for
10 seconds. During this time, Sending appears on
Line 2 of the LCD, followed by Command
Complete when 10 seconds have elapsed.
You can press any function key to restore the Rem
Loopback screen without affecting transmission of
the loopback code.