Paradyne 392xPLUS Network Card User Manual


 
COMSPHERE 392xPlus Modems
3-74 November 1996 3920-A2-GN31-30
The
following sections describe the uses of the T
alk/Data function.
Manual Dialing When the Remote Modem is Configured for Auto-Answer
NOTE
On the remote modem, the Line Current Disconnect configuration
option (refer to the
Line Dialer
section in Chapter 4) must be set to
Disable.
This configuration option does not appear on Models 3920-A1-401,
411 and 3921-B1-001, 011.
If you are originating a call using a telephone and the remote modem is configured for
Auto-Answer, perform the following procedure.
F1
Idle:28.8
Tlk/Data
F2
F3
Press the
key until Tlk/Data appears.
Lift the attached handset and dial the telephone number of the remote modem. When the remote
modem answers, it transmits an answer tone.
F1
Idle:28.8
Tlk/Data
F2
F3
When you hear this tone, immediately select Tlk/Data and hang up the handset. This starts the
handshaking sequence between your modem and the remote modem.
F1
Online:28.8 >
Call_Setup
F2
F3
If this is successful, the modems are in Data mode and
OnLine
appears on the LCD.