Using a browser to complete Model 2616RC configuration 43
Model 2616RC T-DAC User Manual 3 • Configuring the T-DAC for operation
2. Click the System Clocking hyperlink on the 2616RC Configuration Menu to open the System Clocking
Configuration page (see
figure 30).
Figure 30. System Clocking Configuration page, example 2
3. For Clock Reference select secondary(2) or slave(3).
Note
If slave is selected you will not be able to configure the main or fall-
back reference. If you selected
slave(3)
, go to step 6. Otherwise, con-
tinue on to step 4.
4. If you selected
secondary(2)
in step 3, for
Main Reference
select system(500).
5. For
Fallback Reference
select wan-1(1).
6. Click the Submit Query button shown in figure 31.
Figure 31. Clock Reference Submit Query button
7. Select enable(1) to enable the fallback reference clock.
8. Click the
Clock Fallback
Submit Query button shown in figure 32.
Figure 32. Clock Reference Submit Query button