Completing the installation 56
Model 2616RC T-DAC User Manual 3 • Configuring the T-DAC for operation
– To save the displayed data as a text file, use your browser’s Save function (figure 53). Using Netscape or
Internet Explorer, for example.
•Click the File menu.
•Click Save As. A dialog box will appear. Use the dialog to save the data displayed on your browser
(your T-DAC configuration parameters) to a text file.
• Select the folder in which you want to store the file.
•Type a file name.
•Click Save.
Figure 53. Saving the access server flash memory configuration data as a text file
Completing the installation
This section verifies that the Model 2616RC is fully operational.
1. Temporarily disconnect the male ends of both power cords from the power outlet. Wait 30 seconds, then
plug the power cords in again.
2. Verify the green POWER LED is lit. If the POWER LED is flashing green, refer to Chapter 5, “Trouble-
shooting and maintenance”.
3. Verify that the WAN LED illuminates, indicating that the Model 2616RC is synchronized with the T1/E1
signal.
4. After 5 seconds, verify the WAN A Error LED begins flashing, indicating that the T-DAC is satisfied with
the quality of the T1/E1 signal.
5. After 10 seconds, verify the WAN A Error LED extinguishes, indicating that the T-DAC is satisfied with
the network signal and that the link is ready for use.