Patton electronic 2616RC Switch User Manual


 
Using a browser to complete Model 2616RC configuration 48
Model 2616RC T-DAC User Manual 3 • Configuring the T-DAC for operation
Figure 38. Line Type pull-down menu
2. From the Line Coding pull-down menu (figure 39) select dsx1AMI(5) or dsxHDB3(3). Most installations
will use HDB3.
Figure 39. Line Coding pull-down menu with dsx1HDB3(3) selected
3. From the Line Build Out pull-down menu (figure 40) select e1pulse(1).
Figure 40. Line Build Out pull-down menu with e1pulse(1) selected
4. Click the Submit Query button to apply your line interface settings.
At this point the T1/E1 front panel LEDs will become active. The T1/E1 indicator LEDs should now display a
steady green light, indicating the T-DAC has synchronized with the E1 line. If the E1 line is not connected to the
2616RC, T1/E1 link pages will display the hyperlink ALARMS PRESENT (
figure 41) for that T1/E1 link.