CONFIGURATION PAGE FOR COM 2 INTERFACE SETTINGS
You can use this configuration page to set the parameters of the COM2 RS-232 serial interface port.
Figure 33. Configuration Page for COM 2 Interface Settings
Configuration
Item
Default
Setting Description
Serial port function Terminal Use the pull-down menu to select the function for serial port 2 from the pull-down menu: Terminal, Transparent, or
Pelco Prot (protocol).
If the unit will be operated from a terminal, select Terminal. If the port must transmit data transparently, select
Transparent. You can use Pelco Prot to send any kind of control data for a Spectra, Esprit, Genex, or a Pelco
matrix.
Baud rate 19200 Use the pull-down menu to select a transmission rate from 600 to 115200 baud. Refer to Appendix A for settings.
Data bits 8 The number of data bits is set at 8 per character.
Stop bits 1 Use the pull-down menu to select the number of stop bits (1 or 2) per character. Refer to Appendix A for settings.
Parity check None Use the pull-down menu to select the type of parity check (None, Even, or Odd). Refer to Appendix A for settings.