24 C1522M-C (2/05)
Connecting a Single ALM2064 Alarm Interface Unit
To connect a single ALM2064 Alarm Interface Unit:
1. Connect the ALM2064 OUT port to COM 3 on the CM6800-32X6 using the 6-foot (1.8 m) straight data cable supplied with the CM6800.
2. Set SW2, DIP switches 1-8 to the appropriate positions for the local address (default address setting is 1). Refer to the ALM2064
Alarm Interface Unit Installation/Operation Manual for instructions.
COM 1
2
3
4
5
16
6
3231
3
VIDEO
120/230V~
50/60 HZ
25 WATTS
12345678
CONTROL
T
+
T
-
R
+
R
-
2
ALM2064
CONNECT THROUGH
THE "OUT" PORT
COM 3 DEFAULT SETTINGS:
M, RS-485, 19200 BAUD,
1 STOP BIT
NO PARITY, 8 DATA BITS,
STRAIGHT CABLE
(SUPPLIED)
ALM2064
RJ-45 PIN-OUTS
1 Tx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
CM6800 -32X6 COM 3
RJ-45 PIN-OUTS
1 Rx+
2 Rx-
3 NC
4 NC
5 GROUND
6 NC
7 Tx-
8 Tx+
RS-485
010101
Figure 17. Connecting a Single ALM2064 Alarm Interface Unit
Connecting a Single REL2064 Relay Interface Unit
To connect a single REL2064 Relay Interface Unit:
1. Connect the REL2064 OUT port to COM 3 on the CM6800-32X6 using the 6-foot (1.8 m) straight data cable supplied with the CM6800.
2. Set SW2, DIP switches 1-8 to the appropriate positions for the local address (default address setting is 1). Refer to the REL2064
Relay Interface Unit Installation/Operation Manual for instructions.
COM 1
2
3
4
5
16
6
3231
3
VIDEO
120/230V~
50/60 HZ
25 WATTS
12345678
CONTROL
T
+
T
-
R
+
R
-
2
REL2064
CONNECT THROUGH
THE "OUT" PORT
STRAIGHT CABLE
(SUPPLIED)
REL2064
RJ-45 PIN-OUTS
1 Tx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
CM6800-32X6 COM 3
RJ-45 PIN-OUTS
1 Rx+
2 Rx-
3 NC
4 NC
5 GROUND
6 NC
7 Tx-
8 Tx+
COM 3 DEFAULT SETTINGS:
M, RS-485, 19200 BAUD,
1 STOP BIT
NO PARITY, 8 DATA BITS,
010101
Figure 18. Connecting a Single REL2064 Relay Interface Unit