INTERNAL AND EXTERNAL ALARMS
Use the Alarm Contact screens to configure alarm inputs. When an alarm is triggered, the alarm icon and the alarm letter (“I” for internal;
“E” for external) appear on monitors programmed through the Alarm Group screen to display the alarm.
Figure 31. Program an Internal or External Alarm
1. Select the alarm input number in the CONTACT field.
Internal Alarm screen: Configure any of the eight internal alarm inputs on the CM6800 rear panel. Internal inputs are programmable
to associate any camera to any input.
External Alarm screen: Configure any of the external alarms. A maximum of two external ALM2064 Alarm Interface Units can be
connected to the CM6800-32X6, providing up to 128 external alarm inputs.
2. Select ON in the ENABLE field.
3. In the STP matrix, configure up to eight steps to be triggered as a result of this alarm.
a. In the CAM field select a camera (use the logical camera number) to be displayed on a system monitor.
b. In the DWL field, enter the amount of time the camera view is displayed in an alarm sequence; enter a dwell time between 1
and 99 seconds.
c. Optional:
In the CMD field, select a camera operation; if you select a macro, pattern, or preset, enter a valid macro, pattern, or preset
number in the ## field:
MACRO = macro (only the first three steps can be used when selecting a macro; each step must call a macro)
PRES = preset
PATT = pattern
RSCN = random scan
FSCN = frame scan
SSCN = stop scan
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1 CAMERA
2 LOGICAL CAMERA
3 MONITOR
4 ACCESS
5 TIME & DATE
6 PORT
7 PRIORITY
8 SEQUENCE
9 MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
ALARM CONTACTS
1INTERNAL CONTACT
2 EXTERNAL CONTACT
3VIDEO LOSS
4 ALARM GROUP
RETURN
00642
INTERNAL
ALARM MENU
CONTACT: 1 ENABLE: OFF
ACK TYPE: MANUAL TIME OUT: 10
TYPE: NO PRIORITY: 0
STP CAM DWL CMD ## AUX ##
1 0001 01 PRES 13
— — — —
000
2 0001 00
— — — —
00
— — — —
000
3 0001 00
— — — —
00
— — — —
000
4 0001 00
— — — —
00
— — — —
000
5 0001 00
— — — —
00
— — — —
000
6 0001 00
— — — —
00
— — — —
000
7 0001 00
— — — —
00
— — — —
000
8 0001 00
— — — —
00
— — — —
000
GROUP ENABLE
ABCDEFGH
Y NNNNNNN
RETURN
00650
EXTERNAL ALARM MENU
CONTACT: 001 ENABLE: OFF
ACK TYPE: MANUAL TIME OUT: 10
PRIORITY: 0
STP CAM DWL CMD ## AUX ##
1 0001 00
— — — —
00
— — — —
000
2 0001 00
— — — —
00
— — — —
000
3 0001 00
— — — —
00
— — — —
000
4 0001 00
— — — —
00
— — — —
000
5 0001 00
— — — —
00
— — — —
000
6 0001 00
— — — —
00
— — — —
000
7 0001 00
— — — —
00
— — — —
000
8 0001 00
— — — —
00
— — — —
000
GROUP ENABLE
ABCDEFGH
NNNNNNNN
RETURN
00649