46 C1522M-C (2/05)
EVENT TIMERS
You can automate system operation to activate sequences or macros on specific monitors. Events can be scheduled on a daily or weekly
basis, or on a specific date such as a holiday. If you set more than one timer to start at the same time, the timers will run in the following
order of precedence: weekly, special, daily.
On each event timer screen:
•Two methods are provided for selecting the event time: scrolling through time values or entering a valid hour and minute.
• Each timer can activate either a macro or a sequence. Select a value for either the MACRO field or the SEQ field.
•A macro started by an event timer runs until the last step is completed (unless you specify a loop in the macro).
•A sequence started by an event timer runs continuously until another sequence or macro begins, or until a system operator selects a
different camera.
Figure 36. Sample Event Timer Programming
1. Select the timer number.
2. Select ON in the ENABLE field.
3. Set the hour and minute at which the event is to begin (24-hour time) in the TIME field.
4. Special timers only: select the date on which the event is to begin (DD-MM-YY).
5. Select the event to be activated by the event timer.
To select a macro, select a macro number. For a weekly timer specify the macro in the column under the desired day of the week.
To select a sequence, select a sequence number to run on a specific monitor. For a weekly timer specify the sequence in the column
under the desired day of the week
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1 CAMERA
2 LOGICAL CAMERA
3 MONITOR
4 ACCESS
5 TIME & DATE
6 PORT
7 PRIORITY
8 SEQUENCE
9 MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
DAILY TIMER 01
ENABLE: OFF
TIME: 12:02
MACRO 00
MON SEQ
100
200
300
400
500
600
RETURN
00647
EVENT TIMER
1 DAILY TIMER
2WEEKLY TIMER
3 SPECIAL TIMER
RETURN
00648