32 C1522M-C (2/05)
COMMUNICATION PORTS
If you are using any communication port for a device not specified by the default setting, open the Port programming screen to change the
settings.
Table F. Default Port Settings
Port Default Settings
COM 1 MGR, RS-232, 56000 baud, no parity, 8 data bits, 1 stop bit
COM 2 ASCII, RS-232, 9600 baud, no parity, 8 data bits, 1 stop bit
COM 3 M, RS-485, 19200 baud, no parity, 8 data bits, 1 stop bit
COM 4 MUX-GENEX, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
COM 5 KBD-300A, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
PTZ (Port 6) PTZ-P, RS-422, 4800 baud, no parity, 8 data bits, 1 stop bit
KBD960/KBR960 KEYBOARD
Configure the KBD960/KBR960 settings.
1. Set DIP switch 2 to the ON position.
2. Enter Setup Mode. Set the local address (1-8). (Note: the baud rate is set by default to 19200.) Each M device connected to the
CM6800 must have a unique local address. Refer to the KBD960/KBR960 Keyboard Installation/Operation Manual for detailed setup
instructions.
3. Return DIP switch 2 to the OFF position.
4. Press the EXIT icon on the keyboard LCD screen.
GENEX MULTIPLEXER
Access the Camera programming screen and specify MUX control for all cameras connected to the CM6800 through the Genex Multi-
plexer.
Access the CM6800 Camera programming screen to configure the following camera control options for each camera connected to the
CM6800 through the Genex Multiplexer:
• CONTROL: MUX
• PORT ADDRESS: assign the appropriate address. The port address must match the “Unit ID” assigned through the Genex
programming screens.
You must also configure the Genex Multiplexer. Refer to the MX4000 Genex Series Simplex and Duplex Multiplexers Installation/
Operation Manual for instructions on accessing the Advanced System Setup programming screen. Select the following options:
• SPOT MONITOR DISPLAY: TRACK MAIN
• UNIT ID (must match the port address assigned through the CM6800)
• COMM. TYPE: SLAVE (each multiplexer connected to the CM6800 must be in slave mode)