Table C. Default Port Settings
Port Default Settings
COM 1 MGR, RS-232, 56000 baud, no parity, 8 data bits, 1 stop bit
COM 2 ASCII, RS-232, 9600 baud, no parity, 8 data bits, 1 stop bit
COM 3 M, RS-485, 19200 baud, no parity, 8 data bits, 1 stop bit
COM 4 MUX-GENEX, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
COM 5 KBD-300A, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
NOTE: Refer to the
Programming
section for instructions on changing Port settings.
Figure 11. CM6800-32X6 Communication Port Connections and Options
COM 1
2
3
4
5
16
6
3231
3
VIDEO
120/230V~
50/60 HZ
25 WATTS
12345678
CONTROL
T
+
T
-
R
+
R
-
2
KBD960
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
NOTE: TOTAL NUMBER OF
KBD100/200A/300A SERIES
KEYBOARDS CONNECTED
TO THE CM6800-32X6 CANNOT
EXCEED 8
COM 4
GENEX (RS-485)
ALSO PROGRAMMABLE FOR KBD 100/200/300 SERIES,
CM9760-MDA, OR ASCII. MAX # OF DEVICES = 8
CM9505UPS
POWER
SUPPLY
ALM2064
NUMBER SUPPORTED = 2
64 ALARMS X 2 = 128 ALARMS
REL2064
NUMBER SUPPORTED = 2
64 RELAYS X 2 = 128
STRAIGHT
CABLES
KBD960
NUMBER SUPPORTED = 2
COM 5
LOCAL KEYBOARDS (RS-485)
KBD100/200A/300A SERIES
MAX # OF DEVICES = 8
RS-232 NULL
MODEM CABLE
COM 1
PC SETUP
(RS-232)
COM 3
M DEVICES (RS-485)
MAX # OF DEVICES = 6
MAXIMUM DISTANCE FROM CM6800 = 3,940 FT (1,200 M)
USING 24 AWG COPPER, UNSHIELDED TWISTED PAIR; 16 pF PER FT (pF =PICOFARADS)
2
3
4
5
6
7
1 8
2
3
4
5
6
7
1 8
12 V 50 Hz
TRANSFORMER
2
3
4
5
6
7
1 8
COM 4
ALTERNATE
OPTION
COM 2
(RS232)
ASCII CONTROL ONLY
ALTERNATE EQUIPMENT
010101