Pelco CM6800-32X6 Switch User Manual


 
64 C1522M-C (2/05)
Reverse Chronological Pair: M and L
The most recent alarm of a specific group is displayed on one designated monitor, while all other alarms in the group are sequenced on
the second designated monitor. All steps programmed for the alarm contact appear on the designated monitor.
Example: Four alarms set to display on monitors 04 and 05 will appear in the following order:
Monitor 1 Alarm 2 Alarms 3 Alarms 4 Alarms
06 M 1st alarm 2nd alarm 3rd alarm 4th alarm
07 L 1st alarm 1st and 2nd 1st, 2nd, and 3rd
alarms cycle alarms cycle
You must acknowledge alarms in a reverse chronological pair from the display
monitor (M). Then the next most recent alarm moves to the display monitor and the
remaining alarms continue to cycle through the queue monitor (L). This format
requires you to acknowledge each alarm in the reverse order from which they
occurred.
Acknowledging alarms in this example:
Monitor 1st Cycle Next Cycle Next Cycle Next Cycle
06 M Acknowledge Acknowledge Acknowledge Acknowledge
Alarm 4 Alarm 3 Alarm 2 Alarm 1
07 L Alarms 1, 2, Alarms 1 Alarm 1
and 3 cycle and 2 cycle
Salvo Group
Multiple camera views within the alarm contact programming (the “steps”) are displayed simultaneously as a group across a set of
monitors. When a new alarm triggers, all monitors switch to the new alarm at the same time.
When programming a Salvo Group:
Program the Salvo Group to display across a number of monitors equal to the number of steps in the alarm contact(s); for example if
the alarm contact has six steps, set the Salvo Group to display on six monitors. If an alarm contact contains more steps than
monitors defined for the Salvo Group, the additional steps do not appear on a monitor during the alarm.
Each alarm contact assigned to the Salvo Group should contain the same number of steps.
The Salvo Group switches based on the dwell time entered for the first step in the alarm contact.
Example: Two alarm contacts with three steps set to display on three monitors will appear as follows:
Monitor 1 Alarm 2 Alarms Next Display Cycle After Acknowledging 1st Alarm
06 S 1st alarm, step 1 2nd alarm, step 1 1st alarm, step 1 2nd alarm, step 1
07 S 1st alarm, step 2 2nd alarm, step 2 1st alarm, step 2 2nd alarm, step 2
08 S 1st alarm, step 3 2nd alarm, step 3 1st alarm, step 3 2nd alarm, step 3
ALARM MONITOR GROUP SETUP
MON A B C D E F G H
01 ————
02 ————
03 ————
04 ————
05 ————
06 M ————
07 L ————
08 ————