Pelco CM6800-32X6 Switch User Manual


 
C1522M-C (2/05) 43
CAMERA PROGRAMMING
Extended Coaxitron protocol receivers can be operated without any programming changes, other than changing the camera title, if
necessary. For other receiver control protocols, you must select the control type for the device connected to each video input.
If necessary, first program logical camera number.
PROGRAM LOGICAL NUMBERS
Default logical numbers start at 0001 and continue sequentially to 0032. To use a different numbering scheme, program new numbers on
the Logical Camera Number screen.
Figure 34. Program Logical Camera Numbers
The numbers in the PHY columns are the physical input numbers; each represents an actual BNC input on the rear panel of the CM6800
and cannot be changed.
In the LOG field for each physical camera input, assign a valid logical number (0001-9998). A valid number is any number from 0001 to
9998 that has not already been assigned to a physical camera input.
NOTE: If you change a logical number, you cannot control the camera until you select the new logical number from the keyboard.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1 CAMERA
2 LOGICAL CAMERA
3 MONITOR
4 ACCESS
5 TIME & DATE
6 PORT
7 PRIORITY
8 SEQUENCE
9 MACRO
10 ALARM CONTACTS
11 EVENT TIMER
12 SET AUXILIARY
13 SET PASSWORD
14 ABOUT CM6800
ENGLISH
RETURN
00654
LOGICAL CAMERA NUMBER MENU
PHY LOG PHY LOG
01 0001 17 0402
02 0002 18 0403
03 0003 19 0404
04 0004 20 0405
05 0005 21 0500
06 0006 22 0501
07 0007 23 0502
08 0008 24 0503
09 0009 25 0504
10 0201 26 0505
11 0202 27 0601
12 0203 28 0602
13 0301 29 0603
14 0302 30 0604
15 0303 31 0605
16 0401 32 0032
RETURN
00652