Pelco CM6800-32X6 Switch User Manual


 
C1522M-C (2/05) 57
OPERATE SEQUENCES
You can run a scratchpad sequence from an individual monitor or a system sequence on any monitor accessible from the keyboard. When
running a sequence, any cameras not accessible to the keyboard will be bypassed.
A sequence runs continuously until a system operator selects a different camera, or an event timer starts another sequence or macro.
KBD100/200A/300A KEYBOARDS
Run a Sequence
1. Enter a sequence number (1-32). Skip this step to run a
scratchpad sequence.
2. Press and hold the NEXT or PREV key to move forward or
backward through the sequence.
To move through the sequence one camera at a time:
Press the NEXT key to move forward.
Press the PREV key to move backward.
Pause a Sequence
1. Press the HOLD key; monitor displays H.
2. Press the HOLD key to resume.
Stop a Sequence
1. Enter a camera number.
2. Press the CAM key.
KBD960/KBR960 KEYBOARDS
Run a Sequence
1. Select
.
2. Enter a sequence number (1-32 for a system sequence; 0 for the
scratchpad sequence).
3. Select
SEQ
to start the sequence.
OR
1. Select .
2. Select
SEQ
to enter the Sequence Menu.
3. Enter a sequence number (1-32).
OR
Select
or to scroll through available sequences.
4. Select or to start the sequence.
NOTE: You can define a function key to run a sequence. Refer to the
KBD960 Keyboard Installation/Operation Manual for instructions.
Pause a Sequence
1. Select
.
2. Select
or to resume.
Stop a Sequence
1. Select .
OR
1. Enter a camera number.
2. Press the CAM key.