56 C1528M-F (6/05)
MONITOR DISPLAY
Use the Monitor screen to adjust monitor display settings for your system. You can adjust settings for the current monitor only (CURRENT)
or for all system monitors (ALL).
PELCO SWITCHER
MODEL CM6800E
MAIN MENU
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
ALARM CONTACTS
EVENT TIMER
SET AUXILIARY
SET PASSWORD
SYSTEM
ABOUT CM6800E
ENGLISH
RETURN
MONITOR CURRENT
CAMERA NUMBER: ON
CAMERA TITLE: ON
R/X TYPE: ON
MON/ALM NUMBER: ON
MON/ALM STATUS: ON
TIME: ON
DATE: ON
BRIGHTNESS 8
POSITION DISPLAY
SET ALL
RETURN
Figure 44. Monitor Screen
MONITOR: Select CURRENT to program the monitor display for the monitor you are currently operating or ALL for all monitors
connected to the CM6800E.
If you select ALL, you must navigate left or right in the SET ALL field to apply programming changes (refer to the
SET ALL field description).
CAMERA NUMBER: Enable (ON) or disable (OFF) on-screen display of the logical camera
number.
CAMERA TITLE: Enable (ON) or disable (OFF) on-screen display of the camera title
(maximum of 20 alphanumeric characters).
R/X TYPE: Enable (ON) or disable (OFF) on-screen display of the camera control
type. The letter displayed on the monitor reflects the receiver control
type selected in the CONTROL field on the Camera screen.
R/X TYPE DISPLAY VALUES:
E = Coaxitron extended mode (32-bit)
S = Coaxitron standard mode (15-bit)
M = Genex multiplexer
P = PTZ-P (RS-422 through Control Port PTZ-A or PTZ-B)
D = PTZ-D (RS-422 through Control Port PTZ-A or PTZ-B)
NOTE: A 96 x 16 system includes Control Ports PTZ-C and PTZ-D.
0001 E CAM 1
0001 01-JAN-01 01:01:01
0001 E CAM 1
0001 01-JAN-01 01:01:01
0001 E CAM 1
0001 01-JAN-01 01:01:01