Perle Systems 5500320-12 Network Card User Manual


 
76
Collecting Statistics
Edit a Statistics Collection Task
Once the task has been run, only the Statistics Collection task instance name can be edited. To change
target devices and parameters, you must create a new statistics collection task instance.
Input
Frames
Number of good frames received in the following categories;
z Unicast frames
z Broadcast frames
z Multicast frames
z Pause frames
Number of bad frames received in the following categories;
z Undersized frames
z Fragmented frames
z Oversized frames
z Jabber frames
z MAC receive error frames
z FCS error
Output
Frames
Number of good frames transmitted in the following categories;
z Unicast frames
z Broadcast frames
z Multicast frames
z Pause frames
Number of bad frames transmitted in the following categories;
z FCS error
z Deferred frames
z Collision frames
z Excluding late and excessive
z Late
z Excessive
z Single
z Multiple
Packet Sizes Number of frames which fall into the following categories;
z 64 Bytes
z 65 - 127 Bytes
z 128 - 255 Bytes
z 256 - 511 Bytes
z 512 - 1023 Bytes
z Over 1024 Bytes
Update Mode Append - Each new sample collected is added to existing statistic samples
already collected by this task.
Overwrite - Each new sample collected replaces the previously collected
sample. Only one sample (the latest) will be maintained.