Planet Technology IDL-4801 Network Card User Manual


 
IP DSLAM
327
Speed
The actual speed of the interface.
Operational Status
The operational status of the interface.
Admin Status
The administrative status of the interface.
trfclassprofileid
This parameter specifies the traffic class profile identifier to
be associated with the Ethernet interface.
Ctl Pkts Instance Id
This specifies the control packet instance identifier
associated with this interface. If the user does not provide
any instance identifier while creating an interface, an
instance is created internally from the default profile
governed by the macro 2 and associated to the interface.
This will reduce the total number to instances that can be
now created by one. The default instance is governed by
the macro 0.
Ctl Pkts Group Id
This parameter specifies the Control packet instance group
associated with this Ethernet interface. The flows for this
interface shall be mapped to control packet instances as
mapped for the flows corresponding to the groupid
configured in ctlpkt group info command. If this group does
not have entries for all of the flows, then those flows shall
be mapped to the ctlpktinstid. If groupid is 0, then all the
flows shall be mapped to ctlpktinstid.
M2VMacDbId
This field specifies the M2VMac Database Id associated
with this interface. The value 0 means Virtual MAC feature
is disabled on this interface. This field can be modified only
when the interface is disabled.
Mgmt T-VLAN Index
This specifies the value to be used for inserting TVLAN id or
vlan id of the third Vlan tag in the transmitted Ethernet
frames and that is expected in received frames over this
interface. Currently this is configurable and supported only
for management Ethernet interface. For data Ethernet
interface, the value of TVLAN id is configurable and used
from the system sizing table. If the value for TVLAN id
configured on a management Ethernet interface is zero
then third vlan tag shall not be added neither shall it be
supported in received frames. This attribute is applicable
only in stacked-VLAN mode.
References:
z Ethernet stats command.