Q-Logic 59047-10 D Switch User Manual


 
4–Fibre Alliance MIB Objects
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
4-8 59047-10 D
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
Overall status of the connectivity unit. The goal of this object is to be the single
poll point to check the status of the connunit. If there is any other component that
has warning, then this should be set to warning. any of these values may occur
with any of the ConnUnitState values.
Syntax INTEGER
Access read-only
Status mandatory
Return Value Refer to Tabl e 4-3 for connectivity unit return values. Return value will be OK
(3), unless one or more of the following occurs.
other unknown (1)
Table 4-3. QLogic 5000 Series Connectivity Unit Return Values
Status Return Value
If one power supply is reporting Bad
and/or not installed
warning (4)
If both power supplies are reporting Bad
and/or not installed
failed (5)
If one or more cooling fan failed warning (4)
If all cooling fans failed failed (5)
If temperature status = "Warm" warning (4)
If temperature status = "Overheating" failed (5)
If any port down warning (4)
If POST failed failed (5)
If switch Offline or in Diagnostics mode warning (4)
Table 4-2. Switch Operational States (Continued)
Switch State Return State