Q-Logic 59047-10 D Switch User Manual


 
4–Fibre Alliance MIB Objects
connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)
59047-10 D 4-17
connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)
This value defines the event severity that will be logged by this connectivity unit.
All events of severity less than or equal to connUnitEventFilter are logged in
connUnitEventTable.
Syntax FcEventSeverity
Access read-write
Status mandatory
Return Value The switch log level setting. Refer to the following tables for
connUnitEventFilter values.
Table 4-7. connUnitEventFilter Read Return Values
Severity Levels Return Value
Critical Critical (4)
Warn Warning (6)
Info Info (8)
None Unknown (1)
Table 4-8. connUnitEventFilter Control Write Values
Control Value Result
Emergency (2) Critical
Alert (3) Critical
Critical (4) Critical
Error (5) Warn
Warning (6) Warn
Notify (7) Info
Info (8) Info
Debug (9) Info
Mark (10) Info
Unknown (1) None