Q-Logic 59047-10 D Switch User Manual


 
6–QLOGIC MIB Objects
fcQxPortPhysOperStatus (1.3.6.1.4.1.1663.1.3.10.1.1.4)
6-2 59047-10 D
Refer to Tab le 6-2 for fcQxPortPhysAdminStatus write values.
fcQxPortPhysOperStatus (1.3.6.1.4.1.1663.1.3.10.1.1.4)
The current operational status of the FxPort. The testing(3) indicates that no
operational frames can be passed. If fcQxPortPhysAdminStatus is offline(2), then
fcQxPortPhysOperStatus should be offline(2). If fcQxPortPhysAdminStatus is
changed to online(1), then fcQxPortPhysOperStatus should change to online(1). If
the FxPort is ready to accept Fabric Login request from the attached NxPort, it
should proceed and remain in the link- failure(4) state if, and only if, there is a fault
that prevents it from going to the online(1) state.
Syntax INTEGER {
online(1), - Login may proceed
offline(2), - Login cannot proceed
testing(3), - port is under test
linkFailure(4) - failure after online/testing
}
Access read-only
Status current
Return Value Refer to Tab le 6-3 for fcQxPortPhysOperStatus return values.
Table 6-1. fcQxPortPhysAdminStatus Read Return Values
Port Value
Online online (1)
Offline offline (2)
Diagnostics testing (3)
Down offline (2)
Table 6-2. fcQxPortPhysAdminStatus Write Values
Port Value
Online online (1)
Offline offline (2)
Diagnostics testing (3)