Renesas M30850T-EPB Switch User Manual


 
( 35 / 76 )
3.6 A-D Conversion Bypass Capacitor
There is a foot pattern on the M30850T-EPBM board for mounting bypass capacitors for the A-D
conversion circuit. Mount applicable bypass capacitors as occasion demands. Figure 3.8 shows
where they are installed.
IMPORTANT
Note on the A-D Converter:
Because a converter board and other devices are used between the evaluation MCU
and the target system, the A-D converter operates differently from an actual MCU.
Make the final evaluation of the A-D converter using an actual MCU.
Figure 3.8 Foot pattern for the A-D conversion bypass capacitor
C1: VREF--AVSS bypass capacitor
C2: AVCC--AVSS bypass capacitor