Renesas M30850T-EPB Switch User Manual


 
( 68 / 76 )
(2) EMEM Dialog Box is Not Displayed at Debugger Startup (Target Connected)
Table 6.2 Checkpoints of errors when starting up the emulator debugger (target is connected)
Error
Communication error occurred.
Data was not sent to the target.
Target system cannot be properly built.
M3T-PD308F version is not the same
version as the firmware in the target.
Target MCU is in the reset state.
Target MCU cannot be reset.
Target is in "HOLD" state.
Target clock is stopped.
Target MCU is not receiving power.
Checkpoint
Check all emulator debugger settings, interface cable
settings and switches on the rear of the PC7501 match.
See the user's manuals of the PC7501 and emulator
debugger.
(1) Download the proper firmware.
See "4.2 Downloading Firmware" (page 50).
(2) Recheck the connection between the PC7501 and
this product.
See "3.7 Connecting the PC7501" (page 36).
Download the proper firmware.
See "4.2 Downloading Firmware" (page 50).
(1) Check the reset pin of the target system is pulled up.
(2) Check the reset pin of the target system has changed
from "L" to "H" level.
(1) Check pin NMI* is held high.
(2) If in memory expansion mode or microprocessor
mode, check pins RDY* and HOLD* are held high.
(3) If the reset circuit of the target system has a watchdog
timer, disable the timer.
(4) Check that power is properly supplied to the target
system and that the target system is properly grounded.
(5) The program may be uncontrollable in areas where
memory is not allocated. Recheck the map setting.
See "4.3 Starting Up the Emulator Debugger (Setting
the EMEM Dialog Box)" (page 51).
(1) The MCU is either in stop mode or wait mode. Either
reset the MCU or cancel the mode with an interrupt.
See MCU specifications.
(2) The program may be uncontrollable in areas where
memory is not allocated. Recheck the map setting.
See "4.3 Starting Up the Emulator Debugger (Setting
the EMEM Dialog Box)" (page 51).
(1) Check the oscillation circuit of the target system is
oscillating properly.
(2) Check the switches in the emulation probe are correctly
set.
See "3.5 Setting Switches" (page 31).
Check that power is properly supplied to the target system
and that the target system is properly grounded.