Renesas M30850T-EPB Switch User Manual


 
( 40 / 76 )
(3) Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 2)
Figure 3.13 shows how to connect the emulation probe to a 100-pin 0.65-mm-pitch foot pattern on
the target system with the M3T-DIRECT100S (not included), and here following is its procedure. For
details on the M3T-100LCC-DMS and M3T-DIRECT100S, refer to each user's manual.
(1) Attach the M3T-DIRECT100S to the target system.
For details on how to attach the M3T-DIRECT100S to the target system, see the user's manual
of the M3T-DIRECT100S.
(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.
(3) Attach the M30800T-PTC to the M30850T-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 3.13 Connecting to a 100-pin 0.65-mm-pitch foot pattern (2/3)
CAUTION
Notes on Connecting the Target System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulator.
The small connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are
guaranteed for only 20 insertion/removal iterations.
The small connectors of the M30800T-PTC are guaranteed for only 50 insertion/
removal iterations.