Ricoh 406460 Printer User Manual


 
Fax Maintenance
V34 Settings
Equalizer
These selectors set the equalizer's training level to be
applied if training fails due to poor line connection.
[Automatic (Default)/ 4 Points/ 16 Points]
Redialing
Resend when a communication error occurs.
[Disabled (Default)/ Not Disabled]
First TX Speed
Sets the first transmission speed choice, before fallback.
[2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps
/ 12000
Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/
21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/
31200 Bps/ 33600 Bps (Default)]
Symbol Rate
This setting limits the transmission speed range in V.34
mode by masking the desired symbol rate(s).
[Not Used (Default)/ 3429 Sym/Sec
/ 3200 Sym/Sec/ 3000 Sym/Sec
/ 2800 Sym/Sec/ 2400 Sym/Sec]
Factory Default
Factory Default
Not Execute Does not execute anything. Returns to an upper level.
Execute
Resets all the settings to factory default.
Clears/ resets the contents of the controller board
memory (all data programmed by the user, log
data) to factory default.
After
executing, initial setup menu starts after power-on.
CTL Maintenance
CTL Maintenance PDL Mode
ON = "PDL Settings" is shown (Default)
OFF = "PDL Settings" is hidden
Service Program Mode
103
5