Ricoh 406460 Printer User Manual


 
541
Fuser thermistor error
The thermistor output is less than 0°C for 5 seconds after the fusing lamp turns ON.
Disconnected or defective thermistor
Disconnected or defective fusing lamp
1.
Check the harness connection of the thermistor.
2. Replace the fusing unit.
Execute
"Engine Maintenance Menu" to recover the machine after completing the recovery
procedure. Otherwise, the machine continues to
issue this SC code and cannot be operated.
542
Fuser reload error
This SC is issued if one of following conditions occurs:
The fusing
temperature rises 8°C or less in 1.5 seconds; and this continues 5 times consecutively.
-or-
The fusing temperature has not reached 45°C within 9 seconds (after the fusing lamp comes
ON while the machine is warming-up).
-or-
The fusing unit does not attain reload temperature within 35 s. (normal temperature) or 65 s
(lower temperature – the thermistor output is less than 18°C) after the fusing temperature control
starts.
Defective or deformed thermistor
Incorrect power supply input at the main power socket
1.
Defective fusing lamp
6. Troubleshooting
120