541
Fuser thermistor error
The thermistor output is less than 0°C for 5 seconds after the fusing lamp turns ON.
• Disconnected or defective thermistor
• Disconnected or defective fusing lamp
1.
Check the harness connection of the thermistor.
2. Replace the fusing unit.
• Execute
"Engine Maintenance Menu" to recover the machine after completing the recovery
procedure. Otherwise, the machine continues to
•
issue this SC code and cannot be operated.
542
Fuser reload error
This SC is issued if one of following conditions occurs:
The fusing
temperature rises 8°C or less in 1.5 seconds; and this continues 5 times consecutively.
-or-
The fusing temperature has not reached 45°C within 9 seconds (after the fusing lamp comes
ON while the machine is warming-up).
-or-
The fusing unit does not attain reload temperature within 35 s. (normal temperature) or 65 s
(lower temperature – the thermistor output is less than 18°C) after the fusing temperature control
starts.
• Defective or deformed thermistor
• Incorrect power supply input at the main power socket
1.
Defective fusing lamp
6. Troubleshooting
120
6