Ricoh L4160 Printer User Manual


 
Warning / Error Messages
5-17
1
1
1
1
5
Troubleshooting
SYSTEM HALT
Message Cause Solution
There is a slot in which the Eco-car-
tridge has not been inserted more
than a certain time.
Set an Eco-cartridge.
The thermistor connection of a
heater is defective.
Check the thermistor connection of the
drying heater.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
The thermistor is abnormal and the
temperature cannot be read nor-
mally.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
A head heater is disconnected.
The temperature abnormality of the
heater has been detected.
When this error occurred and if the
temperature abnormality cannot be
resolved, the power supply of the
machine is forcibly turned off.
Due to a certain error, the function
cannot be performed.
Return to the local screen, check the
error status and take a countermea-
sure.
There remains received data that
has not yet been printed.
Execute the data clear function.
( P.2-29)
The number of mounted heads is
“0”.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
The media width or the media
length required for printing is not
enough.
Change the media to the one with
enough width or length.
When the media width narrows
because the origin moved, slide the
origin to the right to widen the effective
media width.
The parameter has an error.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
Message Solution
Turn off the main power to the machine and turn it on after a while.
If the same error message appears again, check the number and contact your
local distributor to call for service.
(“000” is the error No.)
ERROR 627
RE- INSERT CARTRI DGE
ERROR 702
THERMISTOR CONNECT
ERROR 703
!EXT HEATER BRK
ERROR 707
!H1 HEATER BREAK
ERROR 710
HEATER TEMP ERROR
ERROR 901
INVAL ID OPERAT ION
ERROR 902
DATA REMAI N
ERROR 90d
NO HEAD SELECT
ERROR 90 f
PRI NT AREA SHORT
ERROR 04
PARAM ROM
SYSTEM HALT
000 : MESSAGE