RuggedCom RSG2288 Switch User Manual


 
Installation
The RS200
0 Family chassis ground connection, shown in Figure 16, uses a #6-
32 screw. It
is recommended to terminate the ground connection in a #6 ring lug,
and to use a torque setting not exceeding 15 in.lbs (1.7 Nm).
Figure 16: Chassis Ground Connection
#6 rin
g
lu
g
stainless steel standoff
#6-32 screw
with ext.
washer.
Terminal
Number
Description Usage
1 PS1 Live / +
PS1 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
2 PS1 Surge Ground
PS1 Surge Ground is connected to the Chassis Ground
via a jumper on the terminal block. Surge Ground is used
as the ground conductor for all surge and transient
suppression circuitry. NOTE: Surge Ground must be
disconnected from Chassis Ground during HIPOT
(dielectric strength) testing.
3 PS1 Neutral / -
PS1 Neutral / - is connected to the negative (-) terminal if
the power source is DC or to the (Neutral) terminal if the
power source is AC.
4 Chassis Ground
Chassis Ground is connected to the Safety Ground
terminal for AC inputs or the equipment ground bus for DC
inputs. Chassis ground connects to both power supply
surge grounds via a removable jumper.
5 PS2 Live / +
PS2 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
6 PS2 Surge Ground
PS2 Surge Ground is connected to the Chassis Ground
via a jumper on the terminal block. Surge Ground is used
as the ground conductor for all surge and transient
suppression circuitry. NOTE: Surge Ground must be
disconnected from Chassis Ground during HIPOT
(dielectric strength) testing.
7 PS2 Neutral / -
PS2 Neutral / - is connected to the negative (-) terminal if
the power source is DC or to the (Neutral) terminal if the
power source is AC.
8 Relay NO Contact Normally open, failsafe relay contact.
9 Relay Common Failsafe relay common contact.
10 Relay NC Contact Normally closed, failsafe relay contact.
Table 5: RS2000 Series Power terminal block connection description
20
RuggedCom
®
RuggedSwitch
®
RSG2288 Installation Guide rev103