RuggedCom RSG2288 Switch User Manual


 
Technical Specifications
3 Technical Specifications
3.1 Power Supply Specifications
Input Range
Power Supply Type
Min Max
Internal
Fuse
Rating
Max. Power
Consumption
3
12 – 24 VDC 10 VDC 36 VDC 6.3A(F)
2
48 VDC 36 VDC 59 VDC 3.15A(T)
2
HI (125/250 VDC)
1
HI (110/230 VAC)
1
88 VDC
85 VAC
300 VDC
264 VAC
2A(T)
1,2
28W
Notes:
1. The “HI” power supply is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse.
3. Power consumption varies based on configuration. 10/100Base-TX ports
consume roughly 1W less than fiber optic ports.
3.2 Failsafe Relay Specifications
Parameter Value (Resistive Load)
Max Switching Voltage 250VAC, 125VDC
Rated Switching Current 2A @ 250VAC
0.15A @ 125VDC, 2A @ 30VDC
Max Switching Capacity 150W, 500VA
3.3 Networking Standards Supported
Standard Description
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX / 100BaseFX
IEEE 802.3z 1000BaseSX/LX
IEEE 802.3ab 1000BaseTx
IEEE 802.3x Full Duplex Operation, Flow Control
IEEE 802.1D MAC Bridges
IEEE 802.1Q VLAN (Virtual LAN) Tagging
IEEE 802.1p Class of Service
IEEE 1588 v2 Precision Time Protocol
36
RuggedCom
®
RuggedSwitch
®
RSG2288 Installation Guide rev103