RuggedCom RSG2288 Switch User Manual


 
Technical Specifications
FXA09 SM SC 9/125 1310 0 5 -37 0 90 37
FXA10 SM LC 9/125 1310 0 5 -37 0 90 37
3.5.2 Gigabit Ethernet (1000Mbps) Optical Specifications
Fixed Gigabit Transceivers
Order
Code
Mode
Connector
Type
Cable Type
(um)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
50/125
FG01 MM LC
62.5/125
850 -9 -2.5 -20 0 0.5 11
FG02 SM SC 9/125 1310 -10 -3 -20 -3 10 10
FG03 SM LC 9/125 1310 -9.5 -3 -21 -3 10 11.5
FG04 SM SC 9/125 1310 -5 0 -20 -3 25 15
FG05 SM LC 9/125 1310 -7 -3 -24 -3 25 17
SFP Gigabit Transceivers
Order
Code
Mode
Connector
Type
Cable Type
(um)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
50/125 0.5
FG51 MM LC
62.5/125
850 -9 -2.5 -20 0
0.3
11
FG52 SM LC 9/125 1310 -9.5 -3 -19 -3 10 9.5
FG53 SM LC 9/125 1310 -7 -3 -23 -3 25 16
FG54
3
SM LC 9/125 1550 0 5 -23 -3 70 23
GBIC Gigabit transceivers
Order
Code
Mode
Connector
Type
Cable Type
(um)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
FG71 SM SC 9/125 1310 -9.5 -3 -21 -3 10 11.5
FG72 SM SC 9/125 1310 -7 -3 -24 -3 25 17
FG73
3
SM SC 9/125 1550 0 5 -23 -3 70 23
Notes:
1. Maximum segment length is greatly dependent on factors such as fiber
quality, and number of patches and splices. Please consult RuggedCom
sales associates when determining maximum segment distances.
2. Distance ratings are typical but will depend on type of cabling, number of
connectors and splices.
3. These transceivers have an operating temperature range of -20°C to +85°C.
All other transceivers have an operating temperature range of -40°C to
+85°C.
4. All optical power figures are listed as dBm averages.
38
RuggedCom
®
RuggedSwitch
®
RSG2288 Installation Guide rev103