RuggedCom RSG2288 Switch User Manual


 
Installation
2.8.2 GBIC Module Removal
GBIC Modules have two locking latches, one on either side of the module, as
shown in Figure 27. To remove a GBIC module, disconnect any cables and
replace the
dust cover to protect the optics. Depress both latches simultaneously
and gently pull the module from the chassis. The module should be immediately
stored in an ESD-safe environment.
Figure 27: Locking latch location on GBIC optical modules
2.8.3 SFP Module Removal
SFP Modules are removed using the metal bail latch located on the top of the
module as shown in Figure 28. To remove the SFP module, disconnect any
cables and r
eplace the dust cover to protect the optics. Grasp the bail latch and
gently pull outwards to unlock and remove the module. Removal of an SFP
module is shown further in Figure 29. The module should be immediately stored
in an ESD-safe environment.
Figure 28: SFP Bail Latch location Figure 29: SFP Removal
30
RuggedCom
®
RuggedSwitch
®
RSG2288 Installation Guide rev103