Parameter address (System memory address)
Parameter
address
(8)
Set value for switch SW3
Details of parameter
(Details --
-
-- See page 12-1)
0 1 2 3 4
00 #0300 #1400 #1500 #1600 #1700 IP address
01 #0301 #1401 #1501 #1601 #1701 IP address
02 #0302 #1402 #1502 #1602 #1702 IP address
03 #0303 #1403 #1503 #1603 #1703 IP address, node number
04 #0304 #1404 #1504 #1604 #1704 Token monitor time (normally set to 10 ms)
05 #0305 #1405 #1505 #1605 #1705 Minimum frame interval (normally set to 0)
06
to
07
#0306
to
#0307
#1406
to
#1407
#1506
to
#1507
#1606
to
#1607
#1706
to
#1707
Reserved area
10 #0310 #1410 #1510 #1610 #1710
Sending area top address of area 1 for
local node (Word address)
11 #0311 #1411 #1511 #1611 #1711
12 #0312 #1412 #1512 #1612 #1712
Sending data length (word) of area 1 for
local node area 1
13 #0313 #1413 #1513 #1613 #1713
14 #0314 #1414 #1514 #1614 #1714
Sending area top address of area 2 for the
local node (Word address)
15 #0315 #1415 #1515 #1615 #1715
16 #0316 #1416 #1516 #1616 #1716
Sending data length (word) of area 2 for
local node
17 #0317 #1417 #1517 #1617 #1717
20 #0320 #1420 #1520 #1620 #1720
Top address (word address) of area 1 on
PC
21 #0321 #1421 #1521 #1621 #1721
22 #0322 #1422 #1522 #1622 #1722 File number of area 1 on PC
23 #0323 #1423 #1523 #1623 #1723 Reserved area
24 #0324 #1424 #1524 #1624 #1724
Top address (word address) of area 2 on
PC
25 #0325 #1425 #1525 #1625 #1725
26 #0326 #1426 #1526 #1626 #1726 File number of area 2 on PC
27 #0327 #1427 #1527 #1627 #1727 Reserved area
30 #0330 #1430 #1530 #1630 #1730
Top address of communication control area
(word address) on PC
31 #0331 #1431 #1531 #1631 #1731
32 #0332 #1432 #1532 #1632 #1732
File number of communication control area
on PC
33 #0333 #1433 #1533 #1633 #1733
Transmission type of communication control
area
33 #0334 #1434 #1534 #1634 #1734
Top address of transmission buffer (word
address)
35 #0335 #1435 #1535 #1635 #1735
36 #0336 #1436 #1536 #1636 #1736 File number of transmission buffer
37 #0337 #1437 #1537 #1637 #1737 Use selection of transmission buffer
40
to
51
#0340
to
#0351
#1440
to
#1451
#1540
to
#1551
#1640
to
#1651
#1740
to
#1751
Node name (ASCII 10 characters)
52
to
57
#0352
to
#0357
#1452
to
#1457
#1552
to
#1557
#1652
to
#1657
#1752
to
#1757
Reserved area
60 #0360 #1460 #1560 #1660 #1760 SEND/RECEIVE instruction timeout time
61
to
76
#0361
to
#0376
#1461
to
#1476
#1561
to
#1576
#1661
to
#1676
#1761
to
#1776
Reserved area
77 #0377 #1477 #1577 #1677 #1777 Start switch
- Parameter addresses on the JW-50FL
Depending on the setting of switch SW3 on the JW-50FL, the addresses of the parameters (in system
memory) will vary, as shown below. In this manual, the parameter addresses in the left column of the