Sharp JW-20FL5 All in One Printer User Manual


 
8-7
Chapter 8: Cyclic Transfer
8
8-3 Parameter settings for cyclic transfers
The parameters related to cyclic transfers are as follows.
Corresponds to 1 to 6 on page 8-1. (For parameter details See Chapter 12.)
- Enter the top address in word units (* above). Pages 8-8 to 8-12.
Ex.: Enter 1600 to 1601 (word address 01C0(H)) as the top address at parameter addresses 10
and 11(8).
Parameter
address
(8)
Description
2
10
Top address (word address) of the data sending areas of own node area 1 *
- Address 10 is for the lower digit and 11 is for the upper digit.
11
3
12
Sending data length (word) of own node area 1
- Address 12 is for the lower digit and 13 is for the upper digit.
13
5
14
Top address (word address) of the data sending areas of own node area 1 *
- Address 14 is for the lower digit and 15 is for the upper digit.
15
6
16
Sending data length (word) of own node area 1
- Address 16 is for the lower digit and 17 is for the upper digit.
17
1
20
Top address (word address) of area 1 on a PC *
- Address 20 is for the lower digit and 21 is for the upper digit.
21
22 File number of area 1 on the PC.
4
24
Top address (word address) of area 2 on a PC *
- Address 24 is for the lower digit and 25 is for the upper digit.
25
26 File number of area 2 on the PC.
Parameter address (Upper digit) 11 (Lower digit) 10
Set value (HEX) 01 C0