Sharp JW-21MN Network Card User Manual


 
11-19
Set connection status of slave station [bit pattern, byte]
Set "connected slave station as 01 and 02, output
error code" in paramenter address 007750(8).
7 6 5 4 3 2 1 0
0 0 0 0 0 1 1 1
007750(8)
Turn "ON" bits 1 and 2 (connects slave station 01 and
02)
Turn "ON" bit 0 (output error code)
Display the contents of parameter address 007750(8)
Screen display of JW-14PG
V2
Set whether the station number information should be output or not
Set whether the station number information should be output or not on the parameter address
007763(8).
007763(8)
Whether the station
number information
should be output or not
00(H): Do not output
01(H): Output
The station number information is output on the next
byte of the flag area (24 bytes.)
This setting is valid when the parameter address is
007767(8) = 80(H).
To the next page
07746
07747
I PARAM.
>07750
From the previous page