Sharp JW-21MN Network Card User Manual


 
11-20
Covert to
hexadecimal
figures
Set top address of flag area
From the previous page
File address: OCT (octal), word
File number/flag: HEX (hexadecimal), byte
Set the top address of the flag area (24 bytes) in order to monitor the communication condition and PC
operation condition on the parameter address 007764 to 007767(8).
Flag area uses 24 bytes regardless number of connecting stations.
007764(8)
007765(8)
007766(8)
007767(8)
Lower
Upper
File number
00(H): Do not output flag
80
(H): Output flag
- In case of setting 0740 (file address 000740(8)), "output flag" in parameter address 007764 to
007767(8). (Example for page 11-10)
Write 000(8) (=00(H)) in parameter address 007766(8).
Write 80(H) in parameter address 007767(8).
Write "000740(8)" in parameter addresses 007764 to 007765(8).
Screen display of JW-14PG
007764(8)
007765(8)
007766(8)
007767(8)
000740
(8)
00
(H)
80
(H)
To the next page
07765 HEX 01
07766 HEX 00
I PARAM.
>07767 HEX 80
(Word display)
(Byte display)