SMC Networks SMC6726AL2 Switch User Manual


 
C
OMMAND
L
INE
I
NTERFACE
4-20
Example
To set the timeout to two minutes, enter this command:
Related Commands
silent-time (4-21)
timeout login response (4-13)
password-thresh
This command sets the password intrusion threshold which limits the
number of failed logon attempts. Use the no form to remove the threshold
value.
Syntax
password-thresh [threshold]
no password-thresh
threshold - The number of allowed password attempts.
(Range: 1-120; 0: no threshold)
Default Setting
The default value is three attempts.
Command Mode
Line Configuration
Command Usage
When the logon attempt threshold is reached, the system interface
becomes silent for a specified amount of time before allowing the next
logon attempt. (Use the silent-time command to set this interval.)
When this threshold is reached for Telnet, the Telnet logon interface
shuts down.
This command applies to both the local console and Telnet
connections.
Console(config-line)#exec-timeout 120
Console(config-line)#