SMC Networks SMC6726AL2 Switch User Manual


 
B
ASIC
C
ONFIGURATION
3-29
Speed – Sets the terminal line’s baud rate for transmit (to terminal) and
receive (from terminal). Set the speed to match the baud rate of the
device connected to the serial port. (Range: 9600, 19200, 38400, 57600,
or 115200 baud; Default: 9600 bps)
Stop Bits – Sets the number of the stop bits transmitted per byte.
(Range:1-2;Default:1stopbit)
Password
3
– Specifies a password for the line connection. When a
connection is started on a line with password protection, the system
prompts for the password. If you enter the correct password, the
system shows a prompt. (Default: No password)
Login
3
– Enables password checking at login. You can select
authentication by a single global password as configured for the
Password parameter, or by passwords set up for specific user-name
accounts. (Default: Local)
Web – Click System, Line, Console. Specify the console port connection
parameters as required, then click Apply.
Figure 3-13 Console Port Settings
3. CLI only.