SMC Networks SMC6726AL2 Switch User Manual


 
S
YSTEM
M
ANAGEMENT
C
OMMANDS
4-69
To send email alerts, the switch first opens a connection, sends all the
email alerts waiting in the queue one by one, and finally closes the
connection.
To open a connection, the switch first selects the server that
successfully sent mail during the last connection, or the first server
configured by this command. If it fails to send mail, the switch selects
the next server in the list and tries to send mail again. If it still fails, the
system will repeat the process at a periodic interval. (A trap will be
triggered if the switch cannot successfully open a connection.)
Example
logging sendmail level
This command sets the severity threshold used to trigger alert messages.
Syntax
logging sendmail level level
level - One of the system message levels (page 4-60). Messages sent
include the selected level down to level 0. (Range: 0-7; Default: 7)
Default Setting
Level 7
Command Mode
Global Configuration
Command Usage
The specified level indicates an event threshold. All events at this level
or higher will be sent to the configured email recipients. (For example,
using Level 7 will report all events from level 7 to level 0.)
Example
This example will send email alerts for system errors from level 4 through
0.
Console(config)#logging sendmail host 192.168.1.200
Console(config)#
Console(config)#logging sendmail level 4
Console(config)#