Sony HDS-X5800 Network Router User Manual


 
2-11 (E)
HDS-X5800
Name of LED
REFERENCE 525
(REF C)
625
1125
750
PROGRESSIVE
Ref. No.
D546
D548
D549
D550
D530
Contents
Status of
REFERENCE C
system
Status
Lights off
The 525 (NTSC)
signal is not inputted
to the REF C
connector.
The 625 (PAL)
signal is not inputted
to the REF C
connector.
The 1125 (HD)
signal is not inputted
to the REF C
connector.
The 750 (HD) signal
is not inputted to the
REF C connector.
It is not the progres-
sive reference
signal.
Error status
All of the 5 LEDs
light off. (Reference
video signal is not
inputted even
though the equip-
ment is set in the
mode that the cross-
points are switched
in synchronous with
reference signal.)
Remedy
Input the reference
video signal to the
REF IN connector.
Cancel the mode to
switch the cross-
points in synchronous
with the reference
signal. (Set the
system to ASYNC.)
. When D11 on the LE-251 lights in red
Name of LED
REFERENCE 525
(REF D)
625
1125
750
PROGRESSIVE
Ref. No.
D552
D553
D555
D556
D532
Contents
Status of
REFERENCE D
system
Status
Lights off
The 525 (NTSC)
signal is not inputted
to the REF D
connector.
The 625 (PAL)
signal is not inputted
to the REF D
connector.
The 1125 (HD)
signal is not inputted
to the REF D
connector.
The 750 (HD) signal
is not inputted to the
REF D connector.
It is not the progres-
sive reference
signal.
Error status
All of the 5 LEDs
light off. (Reference
video signal is not
inputted even
though the equip-
ment is set in the
mode that the cross-
points are switched
in synchronous with
reference signal.)
Remedy
Input the reference
video signal to the
REF IN connector.
Cancel the mode to
switch the cross-
points in synchronous
with the reference
signal. (Set the
system to ASYNC.)
. When D12 on the LE-251 lights in red