Sony UP-2100SD Printer User Manual


 
76
Others
Note
When AUTO LIVE of the FUNCTION-SETUP
menu is set to OFF, the memory image is
displayed on the screen after the image is captured
in memory. In such a case, whenever you store the
image, press the SOURCE/MEMORY button so
that the source image appears on the video
monitor. Displaying the memory image does not
allow to capture the image with the correct timing.
When IMMED. CAP. is set to ON
Note
This mode is effective only the source image is
displayed on the monitor screen. If the memory
image is displayed, the image will not be captured
even if the pulse is sent to the printer. Be sure to
display the source image when sending the pulse.
Design and specifications are subject to change
without notice.
V-SYNC
01 3 82
tRPE
tRPW
vRP
Notation
tRPE
tRPW
VRP
Parameter
Time within which
a remote control
pulse should be
cleared to zero.
Length of a
remote control
pulse.
Amplitude of a
remote control
pulse.
TYP
MIN
3
100
Remarks
This value
is based
on TTL
standards.
Unit
msec
msec
V
MAX
10
5
Captured image
Remote
control
pulse
signal
Specifications (continued)
Using the automatic printing capabilities
(REMOTE 2)
If you send the remote control pulse signals
illustrated through the REMOTE 2 connector, the
printer is remotely controlled according to the
remote control setting. (see page 65)
Turn on the power of the printer and display the
source image on the monitor screen. Send a remote
control pulse signal at the timing shown below.
The timing depends on the setting on item
IMMED. CAP of the FUNCTION SETUP menu.
Remote 2 connector pin assignment
GND
BUSY
MIN
3
2
1
CN5
FL1FL2
Note
The remote control pulse signal examples
introduced here are one of the typical operation
timing. The timing may be affected due to the
selected memory page and print type.
When IMMED. CAP. is set to OFF
V-SYNC
01 56789
Captured image
Notation
tRPE
tRPW
VRP
Parameter
Time within which
a remote control
pulse should be
cleared to zero.
Length of a
remote control
pulse.
Amplitude of a
remote control
pulse.
TYP
MIN
3
100
Remarks
This value
is based
on TTL
standards.
Unit
msec
msec
V
MAX
12
5
MIN
(IN)
BUSY
(OUT)
Remote
control
pulse
signal
VRP
tRPE
tRPW