46 Sun StorageTek 2500 Series Array Hardware Installation Guide • March 2007
and two expansion trays. The cable connections on the B-side are reversed (the cable
from the controller A expansion port goes to the In port of expansion tray 1; the
cable from the controller B expansion port goes to the In port on expansion tray 2)
for maximum redundancy. This pattern continues for each additional tray you add.
Two more SAS cables are required for each additional tray.
FIGURE 2-19 1x3 Array Configuration Cabling
To cable a 1x3 array configuration for maximum redundancy:
1. Locate the Controller A and Controller B expansion ports at the back of the
controller tray (
FIGURE 2-16).
2. Locate In and Out expansion ports at the A-side and B-side back of the
expansion tray (
FIGURE 2-17).
3. Connect one SAS cable between the Controller A expansion port and the A-
side expansion In port of expansion tray 1 (
FIGURE 2-19).
4. Connect one SAS cable between the Controller B expansion Out port and the
B-side expansion In port of expansion tray 2 (
FIGURE 2-19).
5. Connect one SAS cable between the expansion tray 1 Out port and the A-side
expansion In port of expansion tray 2 (
FIGURE 2-19).
AB
Controller Tray
Expansion Tray 1
Expansion Tray 2