Sun Microsystems 2500 Computer Drive User Manual


 
58 Sun StorageTek 2500 Series Array Hardware Installation Guide March 2007
Before you connect data hosts directly to the array, check that the following
prerequisites have been met:
Interface cables are connected and between the HBAs and the array controllers.
SAS cables (1-, 3-, or 6-meters) are available to connect the array host ports to the
data host HBAs.
Each controller module on a controller tray has three SAS host ports (
FIGURE 3-11).
FIGURE 3-11 SAS Data Host Ports (on back of tray).
To Connect Data Hosts to a 2530 Array
1. Locate the host ports at the back of the controller tray (FIGURE 3-11).
If the host port has a plastic protection plug, remove it.
2. Connect one end of the SAS cable to a host port on a controller module.
Host ports are numbered from left to right: host port 1, host port 2, and host
port 3.
3. Connect the other end of each SAS cable to a data host HBA.
4. Affix a label to each end of the cable. See “Host Cable Labeling” on page 59 for
information about cable labels.
5. Repeat these steps for each host-to-controller connection.