Symmetricom XLi IEEE 1588 Clock User Manual


 
XLi IEEE 1588 Clock 123
997-01510-03, Rev. C, 12/12/2006
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
Use the ENTER key to continue to the next screen.
When prompted with “SAVE CHANGES? YES”, press the ENTER key.
To use F131, press the following keys on the front panel keypad:
ENTER 131 ENTER
The keypad display interface displays the following sequence of screens:
PTP AVAILABILITY - OPTION BAY #
READING PTP OPTION CARD - PLEASE WAIT 5 SECONDS
PTP IP ADDRESS (STATIC)
- For PTP master, Option Bay 4 - 010.048.000.103
- For optional PTP slave, Option Bay 2 - 010.048.000.105
PTP SUBNET MASK (STATIC) - 255.255.000.000 (Range:0 to 255 for each 3 digit address.)
PTP DEFAULT GATEWAY (STATIC) - 010.024.000.001 (Range:0 to 255 for each 3-digit
address.)
PTP DHCP - ENABLE (or DISABLE or DHCP) (if enabled, the next three screens provide the IP
Address, Subnet Mask, and Gateway assigned by the DHCP server.)
PTP SYNC INTERVAL - 2 (or 1, 8, 16, 64)
PTP BURST MODE - DISABLE (or ENABLE)
PTP PORT STATE - ENABLE (or DISABLE)
PTP SUBDOMAIN NAME - _DFLT (or _ALT1, _ALT2, _ALT3)
PTP RESET TO FACTORY DFLT? - NO (or YES)
PTP INIT TO USER SETTINGS? - NO (or YES)
PTP CLOCK CONFIG, BAY 2 - MASTER (or SLAVE PRI, SLAVE SEC, SLAVE STBY)
SLAVE SYNC THRESHOLD - 5 microsec (or 1000 microsec)
1
PTP PREFERRED MASTER - DISABLE (or ENABLE)
SAVE CHANGES? - YES (or NO)
In the list above, factory settings are in italics, and factory defaults are in bold italics.
Command Line
The following list is a summary of the F131 commands:
Request a summary of all PTP settings:
F131 B<N>
>F131 B4
ERROR: INVALID COMMAND!
1. Only displayed when PTP CLOCK CONFIG, BAY # is SLAVE PRI/SEC/STBY