Symmetricom XLi IEEE 1588 Clock User Manual


 
66 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
Related functions:
F1 – Time Zone Offset” on page 38
F66 – Daylight Saving Time (DST) Mode” on page 63
F8 - Continuous Time Once-per-Second” on page 46
F9 - Time On Request” on page 49
Command Line
Local Time modifies UTC time to include the Time Zone and Daylight Saving Time adjustments, if
enabled by the user.
Use the following format to display the time mode currently used:
F69<CR>
The XLi responds using the following format:
F69<SEP><TT><CR><LF>
where:
For example, enter:
F69<CR>
XLi gives one of the following responses:
F69 GPS <CR><LF>
F69 UTC <CR><LF>
F69 LOCAL <CR><LF>
F69 STANDARD <CR><LF>
F69 TAI <CR><LF>
To set the time mode, enter a command using the following format:
F69<S><TT><CR>
F
= ASCII character F.
69 = Function number.
<SEP> = One or more separator characters, either space comma or tab characters. For output strings this
will be a single space character.
<TT> = Time Type. Either GPS, UTC, TAI, LOCAL, or STANDARD.
<CR> = Carriage return character.
<LF> = Line feed character.