Symmetricom XLi IEEE 1588 Clock User Manual


 
XLi IEEE 1588 Clock 175
997-01510-03, Rev. C, 12/12/2006
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the primary power."
::= { systemStatusDetail 7 }
statusSecondaryPower OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the secondary power."
::= { systemStatusDetail 8 }
statusRbOsc OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the rubidium oscillator."
::= { systemStatusDetail 9 }
statusDac OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the digital to analog convertor."
::= { systemStatusDetail 10 }
statusFirstTimeLock OBJECT-TYPE
SYNTAX INTEGER {
firstTimeLockedOnce (1),
firstTimeLockedOnceWithinTimeout (2),
firstTimeNotLocked (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of clock since power on.
(1)- indicates the clock has locked at least once since power on.
(2)- indicates the clock has locked since power on but is still within
the power on suppress timeout.
(3)- indicates the clock has not locked since power on."
::= { systemStatusDetail 11 }