Barcode Types A = 2/5 matrix (default)
B = 2/5 industrial
C = 2/5 interleaved
D = Code 11
E = Code BCD matrix
F = Code 39
G = Codabar
H = EAN 8 with HRI
I = EAN 8 without HRI
J = 2/5 matrix (default)
K = EAN 13 with HRI
L = EAN 13 without HRI
M = MSI/modified Plessey
N = UPC A with HRI
O = UPC A without HRI
P = UPC E with HRI
Q = UPC E without HRI
R = Delta Distance (IBM)
S = Code 128
T = EAN 128
All commercial barcodes (for labeling systems) of the H, I, K, L, N, O, P, Q Types can be
extended using the barcodes Add-On 2 or Add-On 5 (see section "Add-On Barcodes").
HRI HRI = Human Readable Index
HRI characters are centered if enough space is left. If the barcode-printout is smaller than
the HRI character field, smaller character density (CPI) is used. Start and stop codes are
not printed as HRI; a space character (SP) will be stored.
Barcode Printing
11