Angenieux 1270A450-005 Switch User Manual


 
Appendix I: Log and SNMP Trap Numbers Datacryptor Ethernet User Manual
Page 106 THALES
Log Trap Errors Hardware
Log Type Code Trap
No.
Severity Message Information
Error
(Hardware)
1 120 Critical Random no. generator fault
Error
(Hardware)
2 120 Critical Real time clock faulty
Error
(Hardware)
3 120 Critical RAM faulty
Error
(Hardware)
4 120 Critical Encrypt Clock Limit
Exceeded
Line clock is too fast for
the unit
Error
(Hardware)
5 120 Critical Decrypt Clock Limit
Exceeded
Line clock is too fast for
the unit
Error
(Hardware)
6 120 Critical Encrypt Clock Stopped
Error
(Hardware)
7 120 Critical Decrypt Clock Stopped
Error
(Hardware)
8 120 Critical Battery may need replacing Battery may be more than
10 years old or exhibiting
symptoms of low voltage
Error
(Hardware)
9 120 Critical Random Number Generator
diagnostics Failed
Error
(Hardware)
10 120 Critical Continuous Random Number
Generator test failed
Error
(Hardware)
11 120 Critical Real Time Clock not set: set
or check battery
Error
(Hardware)
12 120 Critical Hardware Monitor reports
alarm
This can be due to fan,
heat or power failure.
Note that power failure is
reported separately.
Error
(Hardware)
13 120 Critical Power Monitor reports alarm