Appendix A: Device Maintenance
Periodically perform maintenance on your Datacryptor.
Keep components free of dust and other particulate matter.
Check fans for reduced airflow caused by dust build-up and clean as necessary.
Examine cables and fiber for damage and ensure that airflow requirements have been met.
Consult the Environment tab on the Front Panel Viewer’s Properties dialog for readings of
the fan speeds and unit temperature. Make a note of these readings under normal
operating conditions – these readings can be used for comparison in the event of a
Fan/Heat monitor alarm.
Otherwise, no special maintenance is required.
Physical Inspection
The Datacryptor is housed in a tamper evident chassis. Periodically check the chassis for
evidence of tampering. Items to look for include stripped screws and damaged seals.
Figure A-1 Location of Tamper Proof and Identification Labels on the units
The frequency of a physical inspection depends on the value of the intellectual property being
protected and the security of the environment in which the Datacryptor is located. For example,