Angenieux 1270A450-005 Switch User Manual


 
Appendix I: Log and SNMP Trap Numbers Datacryptor Ethernet User Manual
Page 126 THALES
Log Type Code Trap
No.
Severity Message Information
Audit 75 762 Critical Primary mode reboot: KAT
test failure
The encryption algorithm
failed a "Known Answer
Test" (KAT) and has
caused the unit to reboot
to attempt to recover.
Audit 76 763 Critical Secondary mode reboot: KAT
test failure
The encryption algorithm
failed a "Known Answer
Test" (KAT) and has
caused the unit to reboot
to attempt to recover.
Audit 77 764 Major Hot Standby reboot: FPGA
stats mismatch
Hot standby unit has
detected a possible
problem with the
encryption device and has
caused the unit to reboot
to attempt to recover.
Audit 78 765 Major Hot Standby reboot: No
response from Private CR
Hot standby unit may
have detected problem
with Host (Private) port
Ethernet interface which
appears to have stopped
responding and has
caused the unit to reboot
to attempt to recover
Audit 79 766 Major Hot Standby reboot: No
response from Public CR
Hot standby unit may
have detected problem
with Network (Public) port
Ethernet interface which
appears to have stopped
responding and has
caused the unit to reboot
to attempt to recover
Audit 80 767 Major Hot Standby reboot: Failed to
change IP address
Hot Standby unit:
changing of an IP address
appears to have failed and
has caused the unit to
reboot to attempt to
recover
Audit 81 768 Major Detected Primary failure: No
response from Public virtual
IP address
Secondary unit has
detected Primary unit
failure on Network (public)
port side
Audit 82 769 Major Detected primary failure: No
response from Private virtual
IP address
Secondary unit has
detected Primary unit
failure on Host (private)
port side
Audit 83 770 Major Primary: Response back from
Public virtual IP address
Hot standby: primary unit
has detected itself,
probable configuration
error on public side