Toshiba B-EX Label Maker User Manual


 
39
General (2) Tab
[Position Adjustment] Group
[Feed]:
Set a fine adjustment value for the stop position in units of 0.1 mm.
When the value is negative (-), the feed length becomes longer.
The fine adjustment value set by the Position Fine Adjust command [AX] is displayed in the left box.
When the parameter is not retrieved, the value in the left box becomes zero (0).
Default 0.0 mm
Range -50.0 to +50.0 mm
[Cut/Peel Off]:
Set a fine adjustment value for a cut (strip) position in units of 0.1 mm.
When the value is negative (-), the feed length to the cut (strip) position becomes longer.
The fine adjustment value set by the Position Fine Adjust command [AX] is displayed in the left box.
When the parameter is not retrieved, the value in the left box becomes zero (0).
Default 0.0 mm
Range -50.0 to +50.0 mm
[Back Feed]:
Set a fine adjustment value for the back feed length in units of 0.1 mm.
When the value is negative (-), the back feed length becomes shorter.
The fine adjustment value set by the Position Fine Adjust command [AX] is displayed in the left box.
When the parameter is not retrieved, the value in the left box becomes zero (0).
Default 0.0 mm
Range -9.9 to +9.9 mm