Toshiba B-EX Label Maker User Manual


 
40
[X-coordinate]:
Set a fine adjustment value to offset the print position perpendicular to the paper feed direction in units
of 0.1 mm.
When the value is negative (-), the upper right reference coordinate shifts to the left from the zero point.
Default 0.0 mm
Range -99.5 to +99.5 mm
[Tone Adjustment] Group
[Thermal Transfer]:
Set a fine adjustment value for print density in thermal transfer print mode.
The fine adjustment value set by the Print Density Fine Adjust command [AY] is displayed in the left box.
When the parameter is not retrieved, the value in the left box becomes zero (0).
Default 0
Range -20 to +10
[Direct Thermal]:
Set a fine adjustment value for print density in direct thermal print mode.
The fine adjustment value set by the Print Density Fine Adjust command [AY] is displayed in the left box.
When the parameter is not retrieved, the value in the left box becomes zero (0).
Default 0
Range -20 to +10
[Command] Group
[Control Code]:
Select a control code used for command analysis.
Default AUTO
Options AUTO, [ESC] [LF] [NUL], { | }, Manual
[Code 1]:
When "Manual" is selected for the [Control Code], set a code for the first byte in hex. format.
Enter two alphanumeric characters from "0" to "F".
Entries are not case-sensitive.
Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")
Default 1B
Range 20 to FF
[Code 2]:
When "Manual" is selected for the [Control Code], set a code for the second byte in hex. format.
Enter two alphanumeric characters from "0" to "F".
Entries are not case-sensitive.
Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")
Default 0A
Range 20 to FF
[Code 3]:
When "Manual" is selected for the [Control Code], set a code for the third byte in hex. format.
Enter two alphanumeric characters from "0" to "F".
Entries are not case-sensitive.
Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")
Default 00
Range 20 to FF
[BASIC] Group
[Basic Interpreter]:
Select whether or not the basic interpreter is enabled.
Default Disable
Options Disable, Enable
[Basic Trace]:
Select whether or not the basic trace is enabled.
Default Disable
Options Disable, Enable